Kawasaki Z1000 Motorcycle User Manual


 
16-52 ELECTRICAL SYSTEM
Electric Starter System
NOTE
Even if the foregoing checks show the armature t o be
good, i
t may be defective in some manner not readily
detectable with the hand tester. If all other starter motor
and starter motor circuit components check good, but
the st
arter motor still does not turn over or only turns
over weakly, replace the starter motor with a new one.
Brush Lead Inspection
Using the × 1 hand tester range, measure the resis-
tance as shown.
[A] Terminal Bolt and Positive Brush
[B] Brush Plate and Negative Brush
Special Tool - Hand Tester: 57001–1394
If there is not close to zero ohms, the brush lead has
an open. Replace the terminal bolt assembly and/or the
brush holder assembly.
Brush Plate and Terminal Bolt Inspection
Using the highest hand tester range, measure the resis-
tance as shown.
[A] Terminal Bolt and Brush Plate
[B] Terminal Bolt and Right–hand End Cover
Special Tool - Hand Tester: 57001–1394
If there is any reading, the brush holder assembly and/or
terminal bolt assembly have a short. Replace the brush
holder assembly and the t erminal bolt assembly.
Starter Relay Inspection
Remove the battery negative (–) cable from the battery
negative ( –) terminal (see Battery Rem oval).
Remove the right side cover.
Pull out the starter relay.
Disconnect the connector [A]
Disconnect the starter motor cable [B] and battery positive
(+) cable [C] from the starter relay [D].
CAUTION
The battery positive (+) cable with the rubber cap is
connected directly to the battery positive (+) termi-
nal even when the ignition switch off, so take care
not to short the removed cable to chassis ground.