Kawasaki Z1000 Motorcycle User Manual


 
CRANKSHAFT/TR ANSMISSION 9-19
Crankshaft and Connecting Rods
Crankshaft Main Bearing Insert/Journal Wear
Using a plastigage (press gauge) [A], measure the bear-
ing insert/journal [B] clearance.
NOTE
Tighten the crankcase bolts to the specified torque (see
Crankcase Assembly).
Do not
turn the crankshaft during clearance measure-
ment.
Journal clearance less than 0.025 mm (0.00098 in.) can
not be
measured by plastigage, however, using genuine
parts m aintains the minimum standard clearance.
Crankshaft Main Bearing Insert/Journal Clearance
Standard: 0.020 0.044 mm (0.0008 0.0017 in.)
Service Limit: 0.07 mm (0.0028 in.)
If the clearance is within the standard, no bearing replace-
ment is required.
If the clearance is between 0.045 mm (0.0018 in.) and the
service limit 0.07 mm, (0.0028 in.), replace the bearing in-
serts [A] with inserts painted blue [B]. Check insert/journal
clearance with the plastigage. The clearance may exceed
the standard slightly, but it must not be less than the min-
imum in order to avoid bearing seizure.
If the clearance exceeds the service limit, measure the
diameter of the crankshaft main journal.
Crankshaft Main Journal Diameter
Standard: 32.984 33.000 mm (1.2986 1.2992 in.)
Service Limit: 32.96 mm (1.2976 in.)
If any journal has worn past the service limit, replace the
crankshaft with a new one.
If the measured journal diameters are not less than the
service limit, but do not coincide with the original diameter
markings on the crankshaft, make new marks on it.
Crankshaft Main Journal Diameter Marks
None
32.984 32.992 mm (1.2986 1.2989 in.)
1
32.993 33.000 mm (1.2989 1.2992 in.)
: Crankshaft Main Journal Diameter Marks, "1" or no
mark.