BackgroundonIdlerightProgramming:
TheIdlerightunitshipswithfactorydefaultsforagasolinepoweredvehicle.Thesedefaultsare
shownintheIdlerightProgrammingInstructionsbelow.TheIdlerightissuitableforusewith
dieselpoweredvehicles,andsuggestedsettingsfordieselvehiclesarealsoshownbelow.
Ensureprogrammingiscompletedandcorrectbeforeattemptingtostartthevehicleusingthe
Idleright.Programmingoptionsmaybechangedatanytime,anddetectionvoltageand
runtimemayneedtobeincreasedordecreasedfromthedefaultsbaseduponthetypeof
vehicle,sizeofload,andageofthebattery.NotethatreturningtheIdlerightunittofactory
defaultswillreturntheunittoprogrammingsuitableforagasolinevehicle.
IdlerightProgrammingInstructions:
StepsrequiredtoprogramtheIdlerightunit:
Step1: TurnignitiontotheOn/Runposition.
Step2: Within10Seconds,press/releaseprogrammingpushbutton5times.
(TheLEDwillflash6timesrapidlytoindicateentryintoprogramming
mode.)
Step3:Press/ReleasePushbuttonthesamenumberoftimesoftheLocation
inwhichyouwouldliketoprogram.Forexample,ifprogrammingthe
EngineIdleTime,press/releasepushbutton2times.
Step4: Whenatdesiredlocation,press/releasebrakepedaltoselectthe
option.TheLEDwillflashtoindicatetheoptionnumberyouhave
selected.Forexample,tochangetheEngineIdleTimeto30minutes,
press/releasebrakepedal4times.TheLEDindicatorwillflash4times
toconfirm.
Step5: Whenprogrammingforthatlocationiscomplete,turnignitionoff.To
programadditionaloptions,repeattheabovesequence.Ifthe
moduleisleftinprogrammingmodeformorethan3minutes,the
systemwillautomaticallyexit
programmingmode.
Programmingdefaultsarebasedonatypicalgasolineengineandpositiveswitchedwarning
lightsystem.Programmingoptionsthatare
aretherecommendedsettingsfora
typicaldieselenginevehicle.Someadditionalprogrammingmayberequiredinordertofully
optimizeyoursystem’sefficiency.