OPTIONS PROGRAMMING
To Engage Option Programming:
1. Open hood (If no hood pin switch is installed, then ground the Gray wire)
2. Turn Key to the ON position. (Do not start vehicle)
3. Press the valet/program button 5 times. After a few seconds the unit will flash the lights 5 times.
4. Press the valet/program button [again] the number of times that corresponds to the option number desired (1-
22X). You must get a light flash after each button press. If the system did not flash the lights, then it did not
register your press. Press carefully and do not lose count.
5. A) For EZ-90/777: When you reach the desired option #, Press button #1(Lock) or #2 (Unlock) to change the
option. (Some option numbers use ALL 4 remote buttons to select settings)
5. B) For EZ-91 (No remotes) Tap the brake pedal to toggle through the option values: Tap the brake once (lights
flash 1X; Tap the brake pedal again (Lights flash 2X) tap 3 or 4 times for options that have 3 or 4 values.
6. When finished, turn Ignition OFF, close hood (or un-ground Gray wire) and check for changed features.
* = Default Value
Option
#
Option Description Option Values Button #1
LOCK
Button #2
UNLOCK
1. Engine Monitoring Tach (Engine RPM) or Tachless Tach Tachless*
2. Autolock with RPM/Ignition ON or OFF. ON *OFF
3. Door Lock Pulse Time 0.75 Sec. (Standard) OR
3.0 Sec. (European Vacuum)
3 Sec. *0.75 Sec.
4. Double Unlock Pulse Single or Double Unlock Pulse Double *Single
5. OEM Interface
(RS901 MODEL ONLY)
Remote Start w/Single Pulse or
3 Pulses on Green input wire
3 pulse *1 Pulse
6. Passive Starter Disable ON or OFF ON *OFF
7. Horn Chirps on remote start ON or OFF ON *OFF
8. Lock During and After
Remote Start Abort
ON or OFF OFF *ON
9. Tan Wire Output function Trunk or Dome Light Output Dome *Trunk
10. “Wake up” Pulse on Lock
Unlock (1-sec +12V to IGN)
ON or OFF ON *OFF
17