Table 2-7 lists the physical and environmental specifications for Supervisor Engine 32.
Table 2-8 lists Supervisor Engine 32 front panel LEDs and their meanings.
Table 2-7 Supervisor Engine 32 Physical and Environmental Specifications
Item Specification
Dimensions (H x W x D) 1.6 x 15.3 x 16.3 in. (4.06 x 38.86 x 41.40 cm). Occupies one slot in the
chassis.
Weight WS-SUP32-GE-3B—9.8 lb (4.45 kg)
WS-SUP32-10GE-3B—9.6 lb (4.35 kg)
Power requirement
(at 42 VDC)
WS-SUP32-GE-3B—3.69 A
WS-SUP32-10GE-3B—4.19 A
Environment
Operating temperature Certified for operation: 32° to 104°F (0° to 40°C)
Designed and tested for operation: 32° to 130°F (0° to 55°C)
Humidity (RH) ambient
(noncondensing)
10 to 90%
Operating altitude Certified for operation: 0 to 6500 feet (0 to 2000 m)
Designed and tested for operation: –200 to 10,000 feet (–60 to 3000 m)
Table 2-8 Supervisor Engine 32 Front Panel Status LEDs
LED Color and Meaning
STATUS The STATUS LED indicates the status of the supervisor engine.
Green—All diagnostics pass. The supervisor engine is
operational (normal initialization sequence).
Orange—The supervisor engine is booting or running
diagnostics (normal initialization sequence) or an
overtemperature condition has occurred. (A minor temperature
threshold has been exceeded during environmental
monitoring.)
Red—The diagnostic test failed. The supervisor engine is not
operational because a fault occurred during the initialization
sequence or an overtemperature condition has occurred. (A
major temperature threshold has been exceeded during
environmental monitoring.)
SYSTEM The SYSTEM LED indicates the status of the system components.
Green—All chassis environmental monitors are reporting OK.
Orange—A minor hardware problem has been detected.