E
E - 8
INTERIOR
LP GAS DETECTOR
The LP gas detector is located approximately six inches above the floor. LP gas is a
mixture of gases produced and sold commercially as a fuel for heating and cooking
appliances. LP gas is highly flammable and, as a result, can be explosive if ignited
under certain circumstances. LP gas is heavier than air and, if confined in a closed
space, will accumulate close to the floor. When the LP gas concentration in your unit
exceeds 2000 PPM the detector will provide a visual and audible alarm by sounding a
buzzer and flashing the red LED two times per second.
WARNING: Activation of this detector indicates the presence of LP gas,
which can cause an explosion and/or fire. This normally indicates a leak in the
LP gas installation or a LP gas appliance. Extinguish all open flames, open your
windows and door and evacuate the unit immediately. Do not activate any electri-
cal switch. Turn off the LP at your gas bottle(s). DO NOT RE-ENTER YOUR UNIT
UNTIL A QUALIFIED REPAIR TECHNICIAN HAS CORRECTED THE PROBLEM OR
A FIRE DEPARTMENT OFFICIAL HAS CLEARED YOUR UNIT AS SAFE.
OPERATION
Your LP gas detector is wired directly to your vehicle battery and incorporates a 1-amp
in-line fuse. When the device is operating normally the green LED will be lit.
WARNING: It is not recommended that the detector be disconnected
from the battery during periods of storage. There is a small heater on the sensor
of the device, which “burns” away impurities in the air during periods of normal
use. During periods when power is interrupted, impurities can build up on the
sensor. When power is returned to the detector the detector alarm may activate
until the impurities are “burned” off. This could take a number of hours, during
which time the alarm will be constantly “on”.
DETECTOR TEST
Press the test button for 5 to 6 seconds until the alarm sounds then release the test
button. The red LED should flash and the alarm sound for approximately 4 minutes.
This test should be performed at least once a week during normal vehicle operation,
and after periods of storage, and before each trip.
LOW VOLTAGE
Below 10 VDC the detector will continue to operate but will blink alternately green and
orange. Below 8 VDC the unit will behave erratically and will eventually shut off. To
ensure proper operation, do not operate the unit below 10 VDC.
COMPONENT FAILURE
The failure of any circuit component will cause the detector to display a continuous
orange LED fault light and a short beep indicating failure. If this occurs, immediately
contact your dealer or Airstream Customer Service for the name of the nearest detec-
tor service center.
Please read the operating instructions for your detector, which have been supplied
with the paper work of your unit.
WARNING: Have a professional check your system if you have any
doubts.